We
have developed a new technique for quantitative evaluation of adhesive bond
integrity of metals and composites using Angle Beam Ultrasonic Spectroscopy
(ABUS). The novelty of our approach is that it utilizes both normal and
obliquely incident ultrasonic beams on the bond line simultaneously and
measures the frequency response of the reflected ultrasonic signals. The
oblique wave introduces shear stress on the bond line and allows discrimination
of kissing or poor bonds from good bonds. The bond line thickness is determined
from the normal incidence ultrasonic signature and thus the thickness variation
is accounted for in data analysis. The method was further enhanced to utilize
Angle Beam Ultrasonic Spectroscopy for weak bond evaluation by combining it with
a low frequency dynamic load acting as a nonlinear (parametric) enhancement.
The low frequency excitation parameters are set to make the maximum stress
distribution coincide with the bond line. The bond layer properties are
evaluated using Angle Beam Ultrasonic Spectroscopy for different states of
stress of the bondline. Calculations of chemical bonding contributions to the
adhesive strength of adhesive/adherent interfaces have been also performed
which predicts an upper bound to the interfacial properties measured by these
techniques.